| Features |
18
to 36 VDC Input Range
MIL-STD-461 Compatible EMI Filter
(greater than 80%
efficiency)
Up to 4 isolated, Independent Outputs
3.3, 5, 12 and-12 Volt Ouputs
(other
ouputs available)
3U, 47 Position Connector/Compact
PCI Configurations
0.7 inch Max Height (single slot
compatible)
Ruggedized Construction for Harsh
Military Environments
-40 to 85° C Operating Temperature
-55 to 125° C Storage Temperature
On/Off Enable/Inhibit
Output Fault Signature |
| Environmental |
| Rail
temperature |
-40°C
to +71° C |
| Storage
temperature |
-55°C
to +125° C |
| Weight |
1.3
Lbs |
|
| Standards |
MIL-STD-704
MIL-STD-1275 |
|
| Electrical
Specifications |
| Input |
|
| Voltage |
18 — 36
VDC |
| Input
Voltage Transient |
50
VDC @ 100ms |
| Operating
Frequency |
415
Khz (nom) |
| Efficiency
Range |
83%
(typ) |
|
| Output
Power |
|
5
VDC @ 6.5A
3.3 VDC @ 6A
12 VDC @ 1A
-12 VDC @ 1A |
|
| Output
Ripple |
100mv
peak-peak @
BW = DC-20MHZ |
| Voltage
Trim Range |
+/-
10% |
| Output
Regulation |
(+/-
4%) line/ load/ temp |
| Over
Volt Protection |
120%
(typ) |
| Over
Current & Short Circuit Protected |
|
| Isolation |
|
| Input/Output |
100
VDC |
|
|